Deactivate messages about expired obstacle database


If you have an outdated obstacle database in your PowerFLARM device and should you wish to delete this database, e.g. to get rid of the appearing warning messages, please follow this process:

Software version 3.4 or higher is required.

Delete the database on PowerFLARM Portable:

  1. create a text file named FLARMCFG.TXT
  2. insert the following text into the file: $pflac,s,clearobst
  3. copy the file into the root of an empty microSD-card
  4. insert the microSD-card into the slot on your device
  5. please go to menu - info - update.
  6. remove microSD-card after device has successfully updated

Delete the database on PowerFLARM CORE:

  1. create a text file named FLARMCFG.TXT
  2. insert the following text into the file: $pflac,s,clearobst
  3. copy the file into the root of an empty USB-stick 
  4. insert USB-stick into the USB-port on your PowerFLARM Core
  5. switch on your PowerFLARM CORE
  6. remove USB-stick after device has successfully booted (wait 5 minutes to be sure)
Haben Sie Fragen? Anfrage einreichen

0 Kommentare

Bitte melden Sie sich an, um einen Kommentar zu hinterlassen.